VULNERABILITY INTELLIGENCE
CVE-2025-5023
CVSS score7.1 HIGH
EPSS probability0.25%
CISA KEVNot currently listed
Published2025-07-10
Last modified2026-06-17
CVSS vectorCVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:L/I:H/A:H
Description
Use of Hard-coded Credentials vulnerability in Mitsubishi Electric Corporation photovoltaic system monitor “EcoGuideTAB” PV-DR004J all versions and PV-DR004JA all versions allows an attacker within the Wi-Fi communication range between the units of the product (measurement unit and display unit) to disclose information such as generated power and electricity sold back to the grid stored in the product, tamper with or destroy stored or configured information in the product, or cause a Denial-of-Service (DoS) condition on the product, by using hardcoded user ID and password common to the product series obtained by exploiting CVE-2025-5022. The affected products discontinued in 2015, support ended in 2020.
Weakness classification
- Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp: CWE-798