VULNERABILITY INTELLIGENCE
CVE-2024-6326
CVSS score5.5 MEDIUM
EPSS probability0.18%
CISA KEVNot currently listed
Published2024-07-16
Last modified2026-06-17
CVSS vectorCVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N
Description
An exposure of sensitive information vulnerability exists in the Rockwell Automation FactoryTalk® System Service. A malicious user could exploit this vulnerability by starting a back-up or restore process, which temporarily exposes private keys, passwords, pre-shared keys, and database folders when they are temporarily copied to an interim folder. This vulnerability is due to the lack of explicit permissions set on the backup folder. If private keys are obtained by a malicious user, they could impersonate resources on the secured network.
Weakness classification
- PSIRT@rockwellautomation.com: CWE-269
- nvd@nist.gov: CWE-276
Primary references
- PSIRT@rockwellautomation.com — Mitigation, Vendor Advisory
- af854a3a-2127-422b-91ae-364da2661108 — Mitigation, Vendor Advisory