VULNERABILITY INTELLIGENCE

CVE-2024-11676

CVSS score5.3 MEDIUM
EPSS probability0.47%
CISA KEVNot currently listed
Published2024-11-26
Last modified2026-06-17
CVSS vectorCVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Description

A vulnerability was found in CodeAstro Hospital Management System 1.0 and classified as problematic. Affected by this issue is some unknown functionality of the file /backend/admin/his_admin_add_lab_equipment.php of the component Add Laboratory Equipment Page. The manipulation of the argument eqp_code/eqp_name/eqp_vendor/eqp_desc/eqp_dept/eqp_status/eqp_qty leads to cross site scripting. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.

Weakness classification

  • CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
  • CWE-94: Improper Control of Generation of Code ('Code Injection')

Primary references