VULNERABILITY INTELLIGENCE
CVE-2023-51585
CVSS score8.8 HIGH
EPSS probability1.40%
CISA KEVNot currently listed
Published2024-05-03
Last modified2026-06-17
CVSS vectorCVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Description
Voltronic Power ViewPower USBCommEx shutdown Command Injection Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Voltronic Power ViewPower Pro. User interaction is required to exploit this vulnerability in that an administrator must trigger a shutdown operation. The specific flaw exists within the shutdown method. The issue results from the lack of proper validation of a user-supplied string before using it to execute a system call. An attacker can leverage this vulnerability to execute code in the context of the current user. Was ZDI-CAN-22071.
Weakness classification
- zdi-disclosures@trendmicro.com: CWE-78
Primary references
- zdi-disclosures@trendmicro.com — Third Party Advisory
- af854a3a-2127-422b-91ae-364da2661108 — Third Party Advisory