CVE-2023-51584
CVSS score8.8 HIGH
EPSS probability1.13%
CISA KEVNot currently listed
Published2024-05-03
Last modified2026-06-17
CVSS vectorCVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Description
Voltronic Power ViewPower USBCommEx shutdown Exposed Dangerous Method Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Voltronic Power ViewPower Pro. User interaction is required to exploit this vulnerability in that an administrator must trigger a shutdown operation. The specific flaw exists within the shutdown method. The issue results from an exposed dangerous method. An attacker can leverage this vulnerability to execute code in the context of the current user. Was ZDI-CAN-22065.
Weakness classification
- CWE-749: Exposed Dangerous Method or Function
Primary references
- zdi-disclosures@trendmicro.com — Third Party Advisory
- af854a3a-2127-422b-91ae-364da2661108 — Third Party Advisory