VULNERABILITY INTELLIGENCE

CVE-2023-39464

CVSS score7.2 HIGH
EPSS probability1.99%
CISA KEVNot currently listed
Published2024-05-03
Last modified2026-06-17
CVSS vectorCVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H

Description

Triangle MicroWorks SCADA Data Gateway GTWWebMonitorService Unquoted Search Path Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute code on affected installations of Triangle MicroWorks SCADA Data Gateway. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the configuration of the GTWWebMonitorService service. The path to the service executable contains spaces not surrounded by quotations. An attacker can leverage this vulnerability to execute arbitrary code in the context of root. Was ZDI-CAN-20538.

Weakness classification

  • zdi-disclosures@trendmicro.com: CWE-428

Primary references