VULNERABILITY INTELLIGENCE
CVE-2021-37164
CVSS score9.8 CRITICAL
EPSS probability3.40%
CISA KEVNot currently listed
Published2021-08-02
Last modified2026-06-17
CVSS vectorCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Description
A buffer overflow issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. In the tcpTxThread function, the received data is copied to a stack buffer. An off-by-3 condition can occur, resulting in a stack-based buffer overflow.
Weakness classification
- nvd@nist.gov: CWE-787
Primary references
- cve@mitre.org — Broken Link
- cve@mitre.org — Product
- cve@mitre.org — Vendor Advisory
- cve@mitre.org
- af854a3a-2127-422b-91ae-364da2661108 — Broken Link
- af854a3a-2127-422b-91ae-364da2661108 — Product
- af854a3a-2127-422b-91ae-364da2661108 — Vendor Advisory
- af854a3a-2127-422b-91ae-364da2661108