VULNERABILITY INTELLIGENCE
CVE-2021-22797
CVSS score7.8 HIGH
EPSS probability26.10%
CISA KEVNot currently listed
Published2022-04-13
Last modified2026-06-17
CVSS vectorCVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Description
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal) vulnerability exists that could cause malicious script to be deployed in an unauthorized location and may result in code execution on the engineering workstation when a malicious project file is loaded in the engineering software. Affected Product: EcoStruxure Control Expert (V15.0 SP1 and prior, including former Unity Pro), EcoStruxure Process Expert (2020 and prior, including former HDCS), SCADAPack RemoteConnect for x70 (All versions)
Weakness classification
- CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Primary references
- cybersecurity@se.com — Mitigation, Patch, Vendor Advisory
- af854a3a-2127-422b-91ae-364da2661108 — Mitigation, Patch, Vendor Advisory