VULNERABILITY INTELLIGENCE

CVE-2019-13924

CVSS score5.4 MEDIUM
EPSS probability0.83%
CISA KEVNot currently listed
Published2020-02-11
Last modified2026-06-17
CVSS vectorCVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:N

Description

A vulnerability has been identified in SCALANCE S602 (All versions < V4.1), SCALANCE S612 (All versions < V4.1), SCALANCE S623 (All versions < V4.1), SCALANCE S627-2M (All versions < V4.1), SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < 5.2.4), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-200RNA switch family (All versions < V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < 4.1.3). The device does not send the X-Frame-Option Header in the administrative web interface, which makes it vulnerable to Clickjacking attacks. The security vulnerability could be exploited by an attacker that is able to trick an administrative user with a valid session on the target device into clicking on a website controlled by the attacker. The vulnerability could allow an attacker to perform administrative actions via the web interface.

Weakness classification

  • productcert@siemens.com: CWE-693
  • nvd@nist.gov: CWE-1021

Primary references